FARMAX three-phase power conditioners are built with the best-quality filters to deal with surges, sags, over-voltage, noises, notches, long-term interruption, momentary interruption, and frequency variations. So, we assure 100% quality power to enable the best functioning of electric and electronic equipment. They avoid certain unnecessary power issues like data loss, visual and audio disturbances, etc.
Superior quality filters are used in these units - they deal with transient voltage surges, noise, notches, sags, under-voltage, over-voltage, long-term interruption, momentary interruption, and frequency variation. Ultimately, the best power quality is ensured through our power conditioners to any associated equipment.
We are considered as one of the best Power Conditioner manufacturers in Bangalore with more satisfied customers. We manufacture reliable and top-grade Power Conditioners with advanced and latest technologies and also ensure the safety of electronic appliances.
The use of high insulating materials and special shielding techniques results in an attenuating common mode and minimizes transverse mode noise
The core and its magnetic properties are properly selected to provide sufficient leakage inductance. This will give the greatest attenuation of normal mode power line noise possible, consistent with the transfer of fundamental power frequency, while all higher frequencies are blocked
Due to the better regulation, it does not generate common mode impedance coupling effect
Protect against strong lightening, impulse noise, bus short-circuit, accidental discharge of capacitors, etc
Protect the Micro processor based machines and equipment's from damage due to electrical noise, spikes etc.
Enable stable power output even under severe voltage fluctuations zero wave-form distortion
CAPACITY | 6KVA to 150 KVA | ||
---|---|---|---|
Specification | Input Voltage | 340V to 460V or 360V to 460V line-to-line, 3 phase 4-wire system | |
Output Voltage | 415 V3Ph/220V 3Ph as per requirement | ||
Rate of Correction | 70V / 30V/25V per Sec | ||
Response Time | 10 m sec. | ||
Connection | Delta/Star | ||
Efficiency | 98 % | ||
Ratio | 1:1 And 2:1 | ||
Regulation | Better than 3.5% | ||
Power Factor | 0.75 Lead to .75 Lag | ||
Di-Electric strength | 3kv for 60 Sec | ||
Insulation Resistance | Better tan 500 Mega Ohms | ||
Coupling Capacitance | 0.01pF for 100 dB | ||
Leakage Current | < 20 Micro Amps | ||
Common Mode Attenuation | 100 db./ 120 db. | ||
Line Frequency | 47 to 63 HZ | ||
Control Type | Digital Micro controller base | ||
Operating temperature | 0o C - 45o C Ambient | ||
Nature of cooling | Natural air/ Forced air | ||
Protections | Electronic over voltage trip Electronic under voltage trip Overload and short circuit protection Single phasing prevention & cut off Phase reversal protection & cut off |
||
Metering LCD type | Input voltage P-N Output voltage P-P Load current in all phases Frequency |